Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Anus Rectum Colon ; 8(2): 61-69, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38689788

RESUMEN

Objectives: Detailed superiority of CAD EYE (Fujifilm, Tokyo, Japan), an artificial intelligence for polyp detection/diagnosis, compared to endoscopists is not well examined. We examined endoscopist's ability using movie sets of colorectal lesions which were detected and diagnosed by CAD EYE accurately. Methods: Consecutive lesions of ≤10 mm were examined live by CAD EYE from March-June 2022 in our institution. Short unique movie sets of each lesion with and without CAD EYE were recorded simultaneously using two recorders for detection under white light imaging (WLI) and linked color imaging (LCI) and diagnosis under blue laser/light imaging (BLI). Excluding inappropriate movies, 100 lesions detected and diagnosed with CAD EYE accurately were evaluated. Movies without CAD EYE were evaluated first by three trainees and three experts. Subsequently, movies with CAD EYE were examined. The rates of accurate detection and diagnosis were evaluated for both movie sets. Results: Among 100 lesions (mean size: 4.7±2.6 mm; 67 neoplastic/33 hyperplastic), mean accurate detection rates of movies without or with CAD EYE were 78.7%/96.7% under WLI (p<0.01) and 91.3%/97.3% under LCI (p<0.01) for trainees and 85.3%/99.0% under WLI (p<0.01) and 92.6%/99.3% under LCI (p<0.01) for experts. Mean accurate diagnosis rates of movies without or with CAD EYE for BLI were 85.3%/100% for trainees (p<0.01) and 92.3%/100% for experts (p<0.01), respectively. The significant risk factors of not-detected lesions for trainees were right-sided, hyperplastic, not-reddish, in the corner, halation, and inadequate bowel preparation. Conclusions: Unique movie sets with and without CAD EYE could suggest it's efficacy for lesion detection/diagnosis.

2.
J Gastroenterol ; 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38466371

RESUMEN

OBJECTIVE: Prevalence of colonoscopy (CS) is an important countermeasure against colorectal cancer (CRC). In this study, we used large-scale data for a comparison of CS with esophagogastroduodenoscopy (EGD) in Japan. METHODS: This was a retrospective descriptive study. Commercially anonymized patient data were collected from various health insurance societies (JMDC, Inc. Tokyo, Japan) generated from the insurance registry, receipts (inpatient, outpatient, and prescription), and health checkup data. The data also included healthy subjects who had never been examined in a hospital. The data of 2,760,048 persons who were 50-75 years old during January 2012-December 2019 were extracted from the original data source. The annual rate, the prevalence rate (frequency of those undergoing at least one endoscopy during the period), and the percentage of repeaters (undergoing endoscopy at least twice during the period) of CS were calculated and compared to those of EGD. RESULTS: The annual rates in 2012/2015/2019 were 3.4%/4.5%/5.3% for CS, respectively, and increased gradually from 2012 to 2019. Those rates were 7.0%/7.9%/7.4% for EGD, respectively, and did not increase. The prevalence rates of CS and EGD were 25.3% and 36.2%, respectively, among the 137,246 participants over 8 years. The prevalence rates of individuals in their 50 s/60 s/70 s were 23.0%/25.9%/31.4% for CS and 33.0%/37.6%/40.7% for EGD, respectively. The proportions of males/females were 27.9%/20.7% for CS, and 36.4%/35.8% for EGD, respectively. The repeat rates of CS and EGD were 40.3% and 44.8%, respectively, over 8 years. CONCLUSIONS: Using large-scale data, we determined the status of CS and EGD in Japan.

3.
Biol Pharm Bull ; 47(2): 373-382, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38325854

RESUMEN

Patients with diarrhea-predominant irritable bowel syndrome (IBS-D) show excessive peristalsis, and antispasmodic agents may be useful therapeutic agents. There are few reports on the use of Kampo medicines for the treatment of IBS-D. Shakuyakukanzoto (SKT) is a Kampo medicine that is effective against abdominal pain. We examined the relationship between SKT and intestinal peristalsis in an animal model and a prospective study. In the animal model, SKT and its components were administered from the serosal side of the colon and colonic peristalsis was evaluated using intraluminal pressure and spatiotemporal mapping before and after the administration of SKT and its components. In this clinical trial, we used abdominal ultrasonography (US) to obtain long-axis images of the sigmoid colon of 11 patients. The frequency of intestinal peristalsis was measured using US in five patients with SKT and six patients without medication after the ingestion of a test meal. The primary outcome was the frequency of peristalsis. The Clinical Trial Registry Website (Trial No. UMIN-CTR; UMIN000051547). In the animal model, peony did not suppress peristalsis frequency, but SKT (p = 0.005) and glycyrrhiza (p = 0.001) significantly suppressed peristalsis frequency compared with saline and peony. Among the glycyrrhiza components, glycycoumarin and isoliquiritigenin suppressed the peristalsis frequency compared to dimethyl sulfoxide (control) (p = 0.001, 0.01, respectively). In a clinical trial, peristalsis was significantly suppressed after oral administration in patients taking SKT (p = 0.03). Administration of SKT was found to inhibit colonic peristalsis, with glycicumarin and isoliquiritigenin being particularly relevant among its components.


Asunto(s)
Chalconas , Síndrome del Colon Irritable , Humanos , Animales , Peristaltismo , Estudios Prospectivos , Modelos Animales , Diarrea
4.
JGH Open ; 8(1): e13029, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38268964

RESUMEN

Background and Aim: A hemostatic gel, PuraStat (3-D Matrix, Tokyo, Japan), is used for various gastrointestinal hemostasis. In this study, we analyzed the efficacy of PuraStat for perioperative bleeding (POB) and prevention of delayed bleeding (DB) to colorectal cold snare polypectomy (CSP) with continuous anticoagulant. Methods: This was a single-center, retrospective study. Subjects were lesions of 2-9 mm under continuous anticoagulant from 2021 to 2023 and treated with PuraStat for POB. The definition of POB was bleeding which did not stop spontaneously by 1.0-1.5 min after resection and needed hemostasis. Successful hemostasis was defined as cessation of bleeding within 1.0-1.5 min after spraying PuraStat and the rate of it and risk factors of POB were analyzed. For comparison, cases receiving previous CSP without PuraStat were extracted from all cases with CSP (2018-2021), and POB and DB rate (DBR) were analyzed after propensity score matching. Results: One hundred twenty-two lesions (91: direct oral anticoagulant (DOAC), 31: warfarin) with anticoagulant were analyzed and the rate of successful hemostasis with PuraStat was 92.6% (DOAC/warfarin: 93.4%/80.6%, P = 0.01). The rate of DB was 0.0%. Multivariate analysis showed that significant risk factors about unsuccessful hemostasis for POB with PuraStat were lesion size 8-9 mm (P < 0.01), warfarin (P = 0.01), and combination of antiplatelet (P = 0.01). Regarding the comparison about CSP with/without PuraStat, the clipping rate and DBR were 8.5%/94.9% (P < 0.01) and 0%/1.7% (P = 1.0). Conclusion: The effects of PuraStat for POB and DB in colorectal CSP with continuous anticoagulant were acceptable.

6.
Am J Gastroenterol ; 2023 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-37782280

RESUMEN

INTRODUCTION: The efficacy of texture and color enhancement imaging (TXI) in the novel light-emitting diode endoscopic system for polyp detection has not been examined. We aimed to evaluate the noninferiority of the additional 30-second (Add-30-s) observation of the right-sided colon (cecum/ascending colon) with TXI compared with narrow band imaging (NBI) for detecting missed polyps. METHODS: We enrolled 381 patients ≥40 years old who underwent colonoscopy from September 2021 to June 2022 in 3 institutions and randomly assigned them to either the TXI or NBI groups. The right-sided colon was first observed with white light imaging in both groups. Second, after reinsertion from hepatic flexure to the cecum, the right-sided colon was observed with Add-30-s observation of either TXI or NBI. The primary endpoint was to examine the noninferiority of TXI to NBI using the mean number of adenomas and sessile serrated lesions per patient. The secondary ones were to examine adenoma detection rate, adenoma and sessile serrated lesions detection rates, and polyp detection rates in both groups. RESULTS: The TXI and NBI groups consisted of 177 and 181 patients, respectively, and the noninferiorities of the mean number of adenomas and sessile serrated lesions per patients in the second observation were significant (TXI 0.29 [51/177] vs NBI 0.30 [54/181], P < 0.01). The change in adenoma detection rate, adenoma and sessile serrated lesions detection rate, and polyp detection rate for the right-sided colon between the TXI and NBI groups were not different (10.2%/10.5% [ P = 0.81], 13.0%/12.7% [ P = 0.71], and 15.3%/13.8% [ P = 0.71]), respectively. DISCUSSION: Regarding Add-30-s observation of the right-sided colon, TXI was noninferior to NBI.

7.
Gastroenterol Res Pract ; 2023: 6359165, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37808965

RESUMEN

Objectives: Oral sulfate solution (OSS) is used for bowel preparation (BP) during colonoscopy. The way of taking this agent can be used a same-day regimen (only on the day of colonoscopy) and split regimen (the day before and on the day of colonoscopy) for receiving it. In this study, we analyzed the efficacy of a same-day regimen of 480 ml OSS for insufficient bowel preparation (BP) with high-concentrated polyethylene glycol (H-PEG). Materials and Methods: This multicenter retrospective study was conducted from December 2021 to December 2022 at three related institutions on patients aged ≥ 20 years with a fair or poor Aronchick score of BP with 1 l H-PEG in previous colonoscopy. All patients received a low-residual diet and 10 ml of 0.75% picosulfate sodium a day before the colonoscopy and 480 ml of OSS and ≥1 l of water 3 hours before the colonoscopy. We analyzed the rate of improvement with OSS compared to H-PEG and other efficacies, and adverse events (AE). Results: We evaluated 125 cases (77 males) with an average age of 72.1 ± 8.8 years. The completion rate of 480 ml of OSS was 97.6% (122/125). The improvement rate of BP showing good or excellent score with OSS was 70.4% (88/125). Compared OSS with previous H-PEG, the insertion time (min) was 7.0 ± 4.8 vs. 8.1 ± 6.0 (p = 0.01), and the adenoma detection rates were 67.2% vs. 63.2% (p = 0.05). The cleansing time (min) was 131 ± 46 vs. 165 ± 53 (p < 0.01). The rate of AE with OSS was 10.4% (13/125). There were no significant differences about AE in age and gender. The tolerance of OSS compared with H-PEG (good/similar/bad) was 72.0%/24.8%/3.2% (amounts), 26.4%/39.2%/34.4% (taste), and 76.8%/10.4%/12.8% (overall preference), respectively. Conclusions: The same-day regimen of 480 ml OSS effectively improved the insufficient BP of 1 l H-PEG.

8.
Digestion ; 104(6): 468-479, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37619533

RESUMEN

INTRODUCTION: Aortic stenosis (AS) is sometimes associated with gastrointestinal bleeding, and this phenomenon is known as Heyde's syndrome. Such bleeding is most often considered to originate from gastrointestinal angiodysplasias, but the frequency and endoscopic features of such bleeding remain unclear. This study aimed to determine the frequency and endoscopic features of gastrointestinal angiodysplasia in patients with severe AS. PATIENTS AND METHODS: In this multicenter, retrospective study, we evaluated consecutive patients who underwent transcatheter aortic valve implantation (TAVI) with severe AS from May 2016 to December 2019. We extracted the data on the clinicopathological features according to the status of anemia, the proportion of patients who underwent gastrointestinal endoscopic examinations and demonstrated gastrointestinal angiodysplasia, and identified the endoscopic features associated with such patients. RESULTS: In 325 patients, the rates of moderate/severe anemia (hemoglobin < 11 g/dL) were 52%. Regarding medicine, there were no significant differences between the patients with and without moderate/severe anemia. Patients were examined by esophagogastroduodenoscopy (21%), colonoscopy (12%), and balloon-assisted enteroscopy or small bowel capsule endoscopy (1.5%). Patients with moderate/severe anemia had significantly more angiodysplasia (38.3% vs. 7.7%; p < 0.0001) and active bleeding (23.4% vs. 0%; p < 0.01). Angiodysplasia was detected in 21 patients (stomach, n = 9; small intestine, n = 5, and colon, n = 10). CONCLUSIONS: The results suggest, for the first time, that patients with severe AS who underwent TAVI and moderate/severe anemia frequently had gastrointestinal angiodysplasia and active bleeding throughout the entire gastrointestinal tract.


Asunto(s)
Anemia , Angiodisplasia , Estenosis de la Válvula Aórtica , Endoscopía Capsular , Enfermedades del Colon , Humanos , Estudios Retrospectivos , Hemorragia Gastrointestinal/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Angiodisplasia/diagnóstico , Angiodisplasia/diagnóstico por imagen , Anemia/complicaciones
10.
Dig Dis Sci ; 68(5): 2030-2039, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36881195

RESUMEN

INTRODUCTION: SOUTEN (KANEKA Co., Tokyo, Japan) is a unique snare with a disk tip. We analyzed the efficacy of precutting endoscopic mucosal resection with SOUTEN (PEMR-S) for colorectal lesions. METHODS: We retrospectively reviewed 57 lesions of 10-30 mm treated with PEMR-S at our institution from 2017 to 2022. The indications were lesions that were difficult for standard EMR due to size, morphology, and poor elevation by injection. Various therapeutic results of PEMR-S such as en bloc resection, procedure time, and perioperative hemorrhage were analyzed, and the results of 20 lesions of 20-30 mm with PEMR-S were compared to those of lesions with standard EMR (2012-2014) using propensity score matching. Additionally, the stability of the SOUTEN disk tip was analyzed in a laboratory experiment. RESULTS: The polyp size was 16.5 ± 4.2 mm and the non-polypoid morphology rate was 80.7%. Histopathological diagnosis included 10 sessile-serrated lesions, 43 low-grade and high-grade dysplasias, and 4 T1 cancers. After matching, the en bloc resection and histopathological complete resection rates of lesions of 20-30 mm between PEMR-S and standard EMR (90.0% vs. 58.1%, p = 0.03 and 70.0% vs. 45.0%, p = 0.11). The procedure time (min) was 14.8 ± 9.7 and 9.7 ± 8.3 (p < 0.01). The en bloc resection (%) and procedure time of expert/non-expert were 89.7/85.7 (p = 0.96) and 6.1 ± 2.2/18.5 ± 7.2 (p < 0.01). The perioperative bleeding and hemostasis success rates with SOUTEN were 43.9% and 96.0%. In the experiment, the SOUTEN disk tip was fixed stably compared to other EMR snares. CONCLUSIONS: PEMR-S achieved high en bloc resection of colorectal lesions of 20-30 mm though it leaded to long procedure time.


Asunto(s)
Adenoma , Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Humanos , Colonoscopía/métodos , Estudios Retrospectivos , Resección Endoscópica de la Mucosa/métodos , Adenoma/cirugía , Adenoma/patología , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología , Resultado del Tratamiento , Mucosa Intestinal/cirugía , Mucosa Intestinal/patología
11.
NPJ Sci Food ; 7(1): 10, 2023 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-36977699

RESUMEN

Colonic mucus layers protect intestinal tissues against intestinal bacteria. We investigated the effects of dietary fiber and its metabolites on mucus production in the colonic mucosa. Mice were fed a partially hydrolyzed guar gum (PHGG)-containing diet and a fiber-free diet (FFD). The colon mucus layer, fecal short-chain fatty acid (SCFA) levels, and gut microbiota were evaluated. Mucin 2 (MUC2) expression was assessed in SCFA-treated LS174T cells. The role of AKT in MUC2 production was investigated. The mucus layer in the colonic epithelium was significantly increased in the PHGG group compared with that in the FFD group. In the PHGG group, an increase in Bacteroidetes in the stool was observed, and fecal acetate, butyrate, propionate, and succinate levels were significantly increased. However, MUC2 production was significantly increased only in succinate-stimulated LS174T cells. The succinate-induced MUC2 production was associated with AKT phosphorylation. Succinate mediated the PHGG-induced increase in the colon mucus layer.

12.
J Diabetes Investig ; 14(6): 767-773, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36919944

RESUMEN

AIMS/INTRODUCTION: Previous studies have reported that the glucagon-like peptide-1 receptor agonist (GLP-1RA) delays gastric emptying, and gastric emptying was assessed by the 13 C breath test or paracetamol absorption technique. However, neither of them is clinically familiar in real-world clinical practice. The purpose of the present study was to investigate the association between GLP-1RA treatment and gastric residue in an esophagogastroduodenoscopy. MATERIALS AND METHODS: This study was a matched pair case-control study. The study population consisted of 1,128 individuals with diabetes who had esophagogastroduodenoscopy at our clinic between July 2020 and June 2022. To account for differences in characteristics, such as age, sex, insulin treatment and glycated hemoglobin, we carried out a one-to-one nearest neighbor propensity score matching analysis between diabetes patients with and without GLP-1RA treatment. After matching, we compared the presence of gastric residue in an esophagogastroduodenoscopy by the McNemar test between patients with and without GLP-1RA treatment. RESULTS: After the propensity score matching, we selected 205 pairs. In the propensity score-matched comparison, the proportion of gastric residue was statistically significantly higher in the GLP-1RA treatment group (0.49% vs 5.4%, P = 0.004). The details of GLP-1RA prescribed for the 11 patients with gastric residue were liraglutide once daily 1.8 mg (n = 2), dulaglutide once weekly 0.75 mg (n = 5), semaglutide once weekly 0.5 mg (n = 2) and semaglutide once weekly 1.0 mg (n = 2). CONCLUSION: GLP-1RA treatment is associated with gastric residue in an esophagogastroduodenoscopy in patients with diabetes.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hipoglucemiantes , Humanos , Hipoglucemiantes/uso terapéutico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Receptor del Péptido 1 Similar al Glucagón/agonistas , Estudios de Casos y Controles , Liraglutida/uso terapéutico
13.
Clin J Gastroenterol ; 16(1): 32-38, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36369458

RESUMEN

Small intestinal lipomas are rare, but may cause obscure gastrointestinal bleeding. The endoscopic unroofing technique excises only the upper third of the lipoma and allows both histological confirmation and complete treatment with minimal risk of perforation. We present a rare case of obscure gastrointestinal bleeding caused by a jejunal lipoma. A 75-year-old man on antiplatelet therapy presented to our department with melena and anemia. Computed tomography revealed he had a 45-mm jejunal submucosal tumor with fat attenuation. Endoscopic resection using an endoscopic unroofing technique with double balloon enteroscopy was successfully performed. The tumor was confirmed to be a lipoma.


Asunto(s)
Neoplasias del Yeyuno , Lipoma , Masculino , Humanos , Anciano , Enteroscopía de Doble Balón/efectos adversos , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/cirugía , Yeyuno/cirugía , Yeyuno/patología , Neoplasias del Yeyuno/complicaciones , Neoplasias del Yeyuno/diagnóstico por imagen , Neoplasias del Yeyuno/cirugía , Lipoma/complicaciones , Lipoma/diagnóstico por imagen , Lipoma/cirugía
14.
J Neurogastroenterol Motil ; 28(4): 693-705, 2022 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-36250375

RESUMEN

Background/Aims: Several studies have assessed the effect of cool temperature on colonic peristalsis. Transient receptor potential melastatin 8 (TRPM8) is a temperature-sensitive ion channel activated by mild cooling expressed in the colon. We examined the antispasmodic effect of cool temperature on colonic peristalsis in a prospective, randomized, single-blind trial and based on the video imaging and intraluminal pressure of the proximal colon in rats and TRPM8-deficient mice. Methods: In the clinical trial, we randomly assigned a total of 94 patients scheduled to undergo colonoscopy to 2 groups: the mildly cool water (n = 47) and control (n = 47) groups. We used 20 mL of 15°C water for the mildly cool water. The primary outcome was the proportion of subjects with improved peristalsis after treatment. In the rodent proximal colon, we evaluated the intraluminal pressure and performed video imaging of the rodent proximal colon with cool water administration into the colonic lumen. Clinical trial registry website (Trial No. UMIN-CTR; UMIN000030725). Results: In the randomized controlled trial, after treatment, the proportion of subjects with no peristalsis with cool water was significantly higher than that in the placebo group (44.7% vs 23.4%; P < 0.05). In the rodent colon model, cool temperature water was associated with a significant decrease in colonic peristalsis through its suppression of the ratio of peak frequency (P < 0.05). Cool temperature-treated TRPM8-deficient mice did not show a reduction in colonic peristalsis compared with wild-type mice. Conclusion: For the first time, this study demonstrates that cool temperature-dependent suppression of colonic peristalsis may be associated with TRPM8 activation.

15.
Gastroenterol Res Pract ; 2022: 9998280, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35462983

RESUMEN

Background: A compact and cost-effective light source-processor combined 3-color light-emitting diode (LED) endoscopic system (ELUXEO-Lite: EP-6000, Fujifilm Co., Tokyo) with a magnified colonoscope (EC-6600ZP, Fujifilm Co.) has been released. Aims: In this study, we analyzed the efficacy of this system for colorectal tumor characterization with magnified blue light imaging (BLI-LED) and image's subjective and objective evaluations, compared to a magnified blue laser imaging (BLI-LASER) using a standard LASER endoscopic system. Methods: We retrospectively reviewed 37 lesions observed with both BLI-LED and BLI-LASER systems from 2019 using the Japanese narrow band imaging classification. Two representative magnified images, one BLI-LED and one BLI-LASER, of the same area of a lesion were evaluated for diagnostic accuracy and visualization quality by three experts and three non-experts. Their color difference values (CDVs) and brightness values (BVs) were also calculated as objective indicators. Results: Among 37 lesions, mean tumor size was 18.9 ± 13.1 mm, and 21 lesions were nonpolypoid. Histopathology revealed 14 sessile serrated lesions, 7 adenomas, 12 high-grade dysplasias and T1a cancers, and 4 T1b cancers. The diagnostic accuracy rates of BLI-LED/BLI-LASER of experts and non-experts were 90.1% and 87.4% (p = 0.52) and 89.2% and 89.2% (p = 0.99). The percentages of instances where BLI-LED images were better, the two imaging types were equivalent, or BLI-LASER images were better were 16%/83%/1% for experts and 19%/58%/23% for non-experts (p < 0.001). CDVs and BVs between BLI-LED and BLI-LASER were not significantly different (CDVs: p = 0.653, BVs: p = 0.518). Conclusions: BLI-LED using the compact system was noninferior to BLI-LASER for colorectal tumor characterization and image quality.

16.
Case Rep Gastroenterol ; 16(1): 37-43, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35350675

RESUMEN

Case Report: A 65-year-old man without any symptoms received colonoscopy for cancer screening and underwent cold snare polypectomy (CSP) for a 3-mm rectal lesion at a local clinic. A histopathological examination revealed neuroendocrine tumor (NET) G1 with a positive margin. The patient was referred to our hospital for further treatment. Then, the post-CSP scar was removed by endoscopic submucosal dissection (ESD), with a sufficient endoscopically normal margin. Histopathology showed 4 NETs and endocrine cell micronests (ECMs) distant from the post-CSP scar, with a positive lateral margin. We considered that the possibility of other NETs was high. Additional surgery was performed. After a histopathological examination, 11 NETs and ECMs were found in the whole rectum, without lymph node metastasis. The patient had no recurrence at 24 months after surgery. In the past 10 years, we have experienced 4 cases (including the present case) of multiple rectal NETs among 56 cases of rectal NETs of ≤10 mm (7.1%). None of our 4 cases showed any recurrence (follow-up period: 12-32 months). Conclusions: We herein report a case involving a patient with 15 rectal NETs and ECMs. We reviewed our experience with multiple rectal NETs, and the rate of multiple rectal NETs was 7.1%. Endoscopists should consider that multiple lesions may be present in cases of rectal NET and be aware that some cannot be detected endoscopically.

17.
Dig Dis Sci ; 67(12): 5657-5665, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35318554

RESUMEN

INTRODUCTION: An endoscopic system using 5-color light-emitting diodes (LEDs) (EVIS X1; Olympus Co., Tokyo, Japan), which includes texture and color enhancement imaging (TXI), has been released. In this study, we analyzed the effects of TXI on the visibility of non-polypoid colorectal lesions and its diagnostic accuracy. METHODS: We reviewed 101 non-polypoid lesions from 26 patients observed with white light imaging (WLI), narrow band imaging (NBI), and TXI. One representative image of each mode was evaluated by 6 endoscopists using a polyp visibility score of 4 (excellent) to 1 (poor). We calculated the color difference (CD) values for each lesion in the three modes. For tumor characteristics, one representative image of TXI and NBI magnification was evaluated by 3 experts according to a NBI classification. RESULTS: The least squares means [95% confidence interval] of polyp visibility score of TXI (3.42 [3.06-3.77]) was significantly higher than that of WLI (2.85 [2.49-3.20], p < 0.001) but not that of NBI (3.33 [2.98-3.69], p = 0.258). The CD value of TXI (13.3 ± 6.3) was higher than that of WLI (9.7 ± 6.0, p < 0.001) but not that of NBI (13.1 ± 6.8, p = 0.81). For sessile serrated lesions, the CD value of TXI (11.1 ± 4.4) tended to be lower than that of NBI (12.6 ± 6.0, p = 0.07). The diagnostic accuracy and confidence level of magnification for NBI were significantly better than those for TXI (87.1 vs. 80.5%, p = 0.027, 87.5 vs. 62.7%, p < 0.001, respectively). CONCLUSION: TXI showed better visibility than WLI in terms of the endoscopist's score and CD value and may improve polyp detection.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Humanos , Pólipos del Colon/diagnóstico , Colonoscopía/métodos , Imagen de Banda Estrecha/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/patología , Japón , Aumento de la Imagen/métodos , Color
18.
Dig Dis Sci ; 67(7): 3192-3199, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34731360

RESUMEN

BACKGROUND AND AIMS: Recurrence after cold snare polypectomy (CSP) sometimes occurs. We assessed the feasibility of repeat CSP for recurrence after CSP. METHODS: We retrospectively reviewed recurrent lesions after CSP which were resected by repeat CSP from 2016 to 2021 in our institution and analyzed clinical outcomes of repeat CSP, comparing those of non-recurrent 454 lesions receiving standard CSP in 2016 and follow-up colonoscopy. We also analyzed the recurrent rate among cases receiving follow-up in both groups. Indication of repeat CSP was lesions diagnosed as benign tumors of ≤ 10 mm. RESULTS: We analyzed 80 lesions receiving repeat CSP. The polyp size (mean ± standard deviation: SD) was 4.1 ± 2.3 mm (range 2-10 mm). The right-sided colon and non-polypoid morphology rates were 66.3% and 43.8%, respectively. Histopathological diagnosis was 66 adenomas, 12 sessile serrated lesions (SSLs), 1 SSL with dysplasia, and 1 high-grade dysplasia. The procedure time (min, mean ± SD) of repeat CSP was 0.9 ± 0.8. Regarding the comparison of repeat CSP/ standard CSP group, the en bloc resection and histopathological complete resection rates were 78.8%/ 98.0% (p < 0.001) and 43.8%/59.6% (p = 0.007) and the rates of perioperative hemorrhage requiring endoscopic clipping were 1.3%/ 1.0% (p = 0.646). There were no postoperative hemorrhage and perforation in both groups (p = 1.0). Among lesions receiving follow-up colonoscopy, the mean recurrence rates (number, median follow-up period: interquartile) of repeat CSP and standard CSP group were 2.0% (1/50, 12 months: 12-24) versus 0.7% (3/454, 12 months: 12-24) (p = 0.862). CONCLUSIONS: Repeat CSP for benign recurrent lesions after CSP was safe and feasible.


Asunto(s)
Adenoma , Pólipos del Colon , Adenoma/patología , Adenoma/cirugía , Pólipos del Colon/patología , Pólipos del Colon/cirugía , Colonoscopía , Humanos , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/cirugía , Estudios Retrospectivos
19.
Int J Colorectal Dis ; 36(10): 2237-2245, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34406437

RESUMEN

OBJECTIVES: Recently, CAD EYE (Fujifilm, Tokyo, Japan), an artificial intelligence for the lesion recognition (CADe) and the optical diagnosis (CADx) of colorectal polyps, was released. We evaluated the function of CADe and CADx of CAD EYE. METHODS: In this single-center retrospective study, we examined consecutive polyps ≤ 10 mm detected from March to April 2021 to determine whether CAD EYE could recognize them live with both normal- and high-speed observation using white-light imaging (WLI) and linked-color imaging (LCI). We then examined whether the polyps were neoplastic or hyperplastic live with magnified or non-magnified blue-laser imaging (BLI-LASER) or blue-light imaging (BLI-LED) under CAD EYE, comparing the retrospective evaluations with 5 experts and 5 trainees using still images. All polyps were histopathologically examined. RESULTS: We analyzed 100 polyps (mean size 3.9 ± 2.6 mm; 55 neoplastic and 45 hyperplastic lesions) in 25 patients. Regarding CADe, the respective detection rates of CAD EYE with normal- and high-speed observation were 85.0% and 67.0% for WLI (p = 0.002) and 89.0% and 75.0% for LCI (p = 0.009). Regarding CADx for differentiating neoplastic and hyperplastic lesions, the diagnostic accuracy values of CAD EYE with non-magnified and magnified BLI-LASER/LED were 88.8% and 87.8%. Regarding magnified BLI-LASER/LED, the diagnostic accuracy value of CAD EYE was not significantly different from that of experts (92.0%, p = 0.17), but that of trainees (79.0%, p = 0.04). We also found no significant differences in CADe or CADx between LED (53 lesions) and LASER (47 lesions). CONCLUSIONS: CAD EYE was a helpful tool for CADe and CADx in clinical practice.


Asunto(s)
Pólipos del Colon , Inteligencia Artificial , Pólipos del Colon/diagnóstico por imagen , Colonoscopía , Humanos , Imagen de Banda Estrecha , Estudios Retrospectivos
20.
Gan To Kagaku Ryoho ; 48(5): 731-734, 2021 May.
Artículo en Japonés | MEDLINE | ID: mdl-34006725

RESUMEN

We report the case of a 36‒year‒old man who was treated with S‒1 plus oxaliplatin(SOX)therapy for gastric cancer with disseminated intravascular coagulation(DIC). The patient visited our hospital for the treatment of an unresectable type 4 advanced gastric cancer. He had respiratory distress at the first visit. A chest CT scan revealed ground‒glass shadows as well as interstitial and septal thickening diffusely located in both the lungs, which suggested cancerous lymphangiopathy. Moreover, based on blood test results, DIC was diagnosed. After the administration of SOX in combination with recombinant human soluble thrombomodulin, the patient recovered from DIC, and the values of the tumor markers(CEA and CA19‒9) were normalized. After more than 14 months post treatment, the patient has survived without relapse. There are several reports that chemotherapy for gastric cancer is effective for DIC; however, there are no reports on regimens using oxaliplatin. Regimens using this drug may improve the prognosis of gastric cancer complicated by disseminated myelocarcinomatosis and DIC.


Asunto(s)
Coagulación Intravascular Diseminada , Neoplasias Gástricas , Adulto , Coagulación Intravascular Diseminada/tratamiento farmacológico , Coagulación Intravascular Diseminada/etiología , Combinación de Medicamentos , Humanos , Masculino , Recurrencia Local de Neoplasia , Oxaliplatino , Ácido Oxónico , Neoplasias Gástricas/complicaciones , Neoplasias Gástricas/tratamiento farmacológico , Tegafur , Trombomodulina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...